Keil™, An ARM® Company

µVision® User's Guide

Technical Support

On-Line Manuals

µVision® User's Guide

µVision3 Overview
User Interface
Creating Applications
Utilities
Debugging
Debug Commands
Debug Functions
Simulation
Flash Programming
Dialogs
File
Device Database
License Management
Single-User License
Floating-User License
Floating License Administrator
Edit
Find in Files
Configuration
Editor
Colors & Fonts
User Keywords
Shortcut Keys
Templates
View
Symbol Window
Project
Components, Enviornment, and Books
Project Components
Folders/Extensions
Books
Multi-Project
Select Device
Options
Device
Properties
Target
Target (Keil ARM)
Target (Keil C51)
Target (Keil C166)
Target (Keil C251)
Target (GNU ARM)
Target (RealView ARM)
Output
Output (Keil)
Output (GNU ARM)
Output (RealView ARM)
Listing
Listing (Keil)
Listing (GNU ARM)
Listing (RealView ARM)
User
Keil EC++ Compiler
Compiler
Keil CA ARM Compiler
Keil Cx51 Compiler
Keil C166 Compiler
Keil C251 Compiler
GNU ARM C Compiler
RealView ARM C Compiler
Assembler
Keil AA ARM Assembler
Keil Ax51 Assembler
Keil A166 Assembler
Keil A251 Assembler
GNU ARM Assembler
RealView ARM Assembler
Linker
Keil LA Locate
Keil LA Misc
Keil BL51 Locate
Keil BL51 Misc
Keil Lx51 Locate
Keil Lx51 Misc
Keil L166 Locate
Keil L166 Misc
GNU ARM Linker
RealView ARM Linker
Debug
Utilities
Batch Build
Debug
Breakpoints
Debug Settings
Logic Analyzer
Memory Map
Performance Analyzer
Function Editor
Tools
Setup PC-Lint
Customize Tools Menu
SVCS
Configure Version Control
Example Programs
Command Line
Appendix

Logic Analyzer

Current Logic Analyzer Signals
List the current defined Logic Analyzer signals for the active target. Select a signal with the mouse to modified the attributes.
  • Add a variable or VTREG for signal recording with New (Insert key). Delete (Delete key) removes a selected signal.
  • Select a signal name in this list to modify the following settings.
Signal Display
Configures the appearance of a selected signal.
  • Display Type sets the graphical display output to: Analog, Bit (0 or 1), or State (signal transitions).
  • Color sets signal display color.
  • When Hexadecimal Display is enabled signal values are shown as HEX values. When disabled decimal values are shown.
Display Range
Configure the value range of a selected signal for Analog display type with decimal or HEX values.
  • Min Value sets the minimum value. 
  • Max Value sets the maximum value. 
Display Formula (Signal & Mask) >> Shift
Extract specific bits from a signal value for displaying.
  • And Mask specifies a AND mask for the value display of a signal.
  • Shift Right specifies a shift right factor for the value display of a signal.
Export / Import
Store and restore the current Logic Analyzer Setup.
  • Export Signal Definitions create a file with the current setup of the signal definitions.
  • Import Signal Definitions restore a signal definition setup from a file.
Kill All
Delete all defined signals for the active target.
Close
Closes the dialog.

For additional information refer to Logic Analyzer Setup.