Technical Support Support Resources
Product Information |
ULINK: Startup Problems with Infineon OCDS on XC16XInformation in this article applies to:
QUESTIONWe have a problem with OCDS debugging on a new board using XC167. The board is straightforward; we are setting the XC167 in single-chip mode with /EA==1 (no pull-down). When I try to connect with OCDS, µVision replies that it cannot detect the hardware and displays a message box: Error: Target DLL has been cancelled. Debugger aborted! If the board is not powered, or in bootstrap mode (using the /RD pull down), µVision shows the correct error message. Do you have any idea on the mistake? ANSWERThere are a couple of potential issues that need to be taken care of when using OCDS. Check the following:
MORE INFORMATION
SEE ALSO
ULINK: XC16X OCDS Interface does not work Last Reviewed: Tuesday, January 5, 2021 | ||||||||||
|
Arm’s Privacy Policy has been updated. By continuing to use our site, you consent to Arm’s Privacy Policy. Please review our Privacy Policy to learn more about our collection, use and transfers