MCB2100: CAN Interface ProblemsInformation in this article applies to:
SYMPTOMThe CAN I/O port on the MCB2100 Board does not work as it should. CAUSEAccording to the schematics, the pins CANL and CANH are wired to pin 2 and 7 of the DB-9 connector. However, they are actually connected to pin 4 and pin 8. RESOLUTIONPin 4 and pin 8 are not used on the CAN connector. So the workaround is to connect pin 2 to pin 4 and pin 7 to pin 8 underneath the DB9 connectors. STATUSMost of the MCB2100 Version 2 boards are shipped with a correction for that error. So check your Board first to see if it already has this fix. MORE INFORMATION
SEE ALSOATTACHED FILESRequest the files attached to this knowledgebase article. Last Reviewed: Tuesday, January 19, 2021 | ||||||||||
|
|||||||||||