MCB2100: Memory Address Mismatch at 0x20Information in this article applies to:
QUESTIONI'm using the Keil MCB2100 Board together with ULINK. Whenever I start the debugger, I get a message box with the following: Error Memory Mismatch! Address: 0x00000020 Value = 0xB0 Expected = 0x58 What can be wrong? ANSWERIt appears that the device is in Serial Flash Download Mode and the Interrupt vector gets redirected. Check to see if the jumper settings match the default setting. The MCB2100 Board is shipped with the following configuration: Jumper State Description -------------------------------------------------------------- J1 - ISP ON Enable In-System Programming via COM0. J2 - AV ON Connect POT1 potentiometer to AIN0. J3 - 3.3V ON Connect 3.3V to CPU. J4 - 1.8V ON Connect 1.8V to CPU. J5 - V3A ON Connect analog reference voltage to CPU. J6 - LED ON Enable Port1.16 - Port1.23 LED's. J7 - INT1 ON Enable INT1 Push Button. J8 - ETM OFF Disable Embedded Trace. J9 - JTAG ON Enable JTAG interface. J10 - RST ON Enable Reset via COM0. J11 - CAN ON Enable CAN driver. J12 - RD1 ON Connect RD1 CAN receiver input. J13 - RD2 ON Connect RD2 CAN receiver input. -------------------------------------------------------------- If J1 and J7 are OFF, the LPC21xx device may go into Flash Download Mode on Reset. A similar problem may occur if you have connected the MCB2100 COM0 port to a PC. In this case, disconnect J1 and J10. MORE INFORMATION
SEE ALSO
Last Reviewed: Tuesday, January 5, 2021 | ||||||||||
|
|||||||||||
Arm’s Privacy Policy has been updated. By continuing to use our site, you consent to Arm’s Privacy Policy. Please review our Privacy Policy to learn more about our collection, use and transfers
of your data.