Technical Support Support Resources
Product Information | MCB900: POWER SUPPLY PROBLEM ON MCB900 V4Information in this article applies to:
QUESTIONI have a problem with the power supply on MCB900. The ADC generates wrong results because the voltage regulator appears to be oscillating. How can I solve that issue? ANSWERThere was a problem on early versions of the MCB900 V4 Board. The capacitor C10 should be a 10uF Tantalum (+ polarity on label www.keil.com/MCB900). If you change C10, the board will work fine. MORE INFORMATION
SEE ALSOLast Reviewed: Saturday, November 18, 2006 | ||||
| |||||