µVision creates several output files that can be configured in
this dialog page. Refer to File
Types for a list of output files.
Select Folder for Objects...
Sets the folder for storing the the object
files.
Name of Executable
Specifies the name of the executable that gets
generated during the build or rebuild process. This executable is
loaded into the debugger and downloaded to hardware by
default.
Create Executable
Instructs µVision to generate an executable
application program, which gets the name specified in Name of
Executable.
Debug Information
Generates debug information for testing the
application. Enable the option to access function names, variables
names, or the source code within the µVision Debugger. Disable the
option to create a release version.
Changes the address order in the Intel HEX-386 file or
banking applications. It allows generating the image for a target
hardware with 32KB common area and multiple 32KB
code banks. This Intel HEX-386 file contains the
complete image of the application code in the following address
ranges:
0x000000-0x007FFF: Common Area
0x008000-0x00FFFF: Code Bank 0
0x010000-0x017FFF: Code Bank 1
0x018000-0x01FFFF: Code Bank 2
And so on. Typical, this file can be directly programmed
into ROM devices for such a hardware.
Create HEX File
Creates an Intel HEX file. HEX files are used
to download the software into an PROM Programmer or other
utilities.
HEX Format
Specifies the HEX file format, which depends on the
size of the application program. Ensure that the PROM Programmer in
use supports the selected format.
Create Library
Generates a library file that can be used in other
projects.
Create Batch File
Generates a batch file (*.BAT) with commands that
reproduce the "Rebuild" process. "Rebuild" the target to create the
file. The "Build" process does not alter nor creates the file.
However, with this flag set, the "Build" process compiles and links
all files, just like a "Rebuild". The batch file name is inherited
from the current target name. The file is saved in the root
directory of the project. Use the batch file to "Rebuild" the
project without using the µVision IDE.
This site uses cookies to store information on your computer. By continuing to use our site, you consent to our cookies.
ARM websites use two types of cookie: (1) those that enable the site to function and perform as required; and (2) analytical cookies which anonymously track visitors only while using the site. If you are not happy with this use of these cookies please review our Privacy Policy to learn how they can be disabled. By disabling cookies some features of the site will not work.