Keil Logo

Trace Data Not Synchronized

Trace Data Not Synchronized offers solutions for the event that wrong or no data are displayed in µVision Windows.

The Trace Status delivers useful information about the status of capturing trace data. When either of the error message is displayed, follow the corrective checks:

  1. Is the Core Clock set equal to the frequency of the system clock? Refer to Trace Settings.
  2. Did the system clock change its value after RESET, and, as a consequence, the Core Clock value is not set correctly?.
  3. Is Trace enabled? Refer to Trace Settings.
  4. Is the Max Clock for the debug Port set too high?