 | ULINK2 User's Guide |  |
|
|
| Enable Serial Wire TraceTo enable Serial Wire Trace on Toshiba TMPM330 devices: - Use a ULINK2 connector interface that supports Serial Wire, and connect ULINK2 to the board and to the host computer.
- Configure µVision to capture Serial Wire Trace data as described in the manual 32-bit RISC Microprocessor - TMPM330 Family, chapters Port A (PA0-PA7), and Port B (PB0-PB7).
Configure µVision to capture Serial Wire Trace data- Open the dialog Options for Target — Debug.

- Enable Use, select ULINK Cortex Debugger, and click Settings open the Target Driver Setup dialog.

- Enable SWJ and select SW from the Port drop-down list.
- Click the Trace tab.

- Set Trace Enable.
- Set the Trace Port to Serial Wire Output - Manchester.
- Enable Autodetect for the SWO Clock.
- Make sure the Core Clock is set correctly.
Start the debugging session and verify the captured trace data with a µVision window. Note - Use the examples delivered with the Keil board MCBTMPM330 as a reference.
|
|