 | ULINK2 User's Guide |  |
|
|
| Enable Serial Wire TraceTo enable Serial Wire Trace on Luminary LM3Sx devices: - Use a ULINK2 connector interface that supports Serial Wire, and connect ULINK2 to the board and to the host computer.
- Configure µVision to capture Serial Wire Trace data.
Configure µVision to capture Serial Wire Trace data- Open the dialog Options for Target — Debug.
- Enable Use, select ULINK Cortex Debugger, and click Settings to open the Target Driver Setup dialog.

- Enable SWJ and select SW.

- Click the Trace tab.

- Set Trace Enable and Autodetect.
- The Core Clock must correspond to the device configuration.
Start the debugging session and verify the captured trace data with a µVision window. Note - Use the examples delivered with the Luminary board ek-lm3s6965 as a reference.
|
|