Keil™, An ARM® Company

MCBXC800 User's Guide

Configuring DAS

To select the Debug Access Server (DAS) driver:

  • Open the Project — Options for Target dialog.
  • Select the Debug tab.
  • Click the Use button
  • Select the Infineon DAS Client for XC800 from the drop-down.
  • Check the Load Application at Startup and the Run to main() options.

    OCDS Select DAS

  • Click on Settings to open the Target Driver Setup dialog.


To select the Infineon DAS interface as the Flash Programming Tool:

  • Open the Project — Options for Target dialog.
  • Select the Utilities tab.
  • Click the Use Target Driver for Flash Programming button
  • Select the Infineon DAS Client for XC800 from the drop-down.
  • Check the Update Target before Debugging option.

    OCDS Flash Driver Selection

  • Click on Settings to open the Target Driver Setup dialog.

    OCDS Flash Driver -- Settings

Enable the Update Target before Debugging to download the program to the Flash ROM when the debugger starts up.