| Connecting with ULINKTo use the MCB2100 Evaluation Board with ULINK, you must: - Connect the ULINK to the PC via a standard USB cable.
- Connect ULINK to the JTAG connector of the MCB2100 board.
- Make sure that J9 - JTAG is ON.
- Connect power to the board using a 6V - 9V DC, 150mA power supply.
The following picture shows how to connect ULINK to the MCB2100 board. 
Note - If your application program puts the ARM device in idle or power-down mode, the Embedded ICE in the LPC2000 core (and the ULINK) stops working. Therefore, do not put the ARM device into power saving modes during the software development cycle.
|
|