Technical Support Support Resources Product Information | MCB520: MONITOR EXECUTION SPEEDInformation in this article applies to:
QUESTIONI am using the MCB520 board and I would like to know if the Monitor is using the 520 device with four oscillator cycles per machine cycle or 12 oscillator cycles per machine cycle. If it is 12 then is it possible to obtain a version of the monitor that uses the faster speed? ANSWERBy default the Dallas 520 device powers up in the four oscillator cycles per machine cycle state (refer to the default settings for CD0 and CD1 in the PMR Power Management Register) and it is this state that the monitor uses. Note that the timers may be individually configured to use the faster or slower state. The default is the slower state in order to make them compatible with 'standard' 8051s. MORE INFORMATION
Last Reviewed: Tuesday, July 19, 2005 | |||||||
| ||||||||