Keil Logo

ULINK: No Algorithm Found for Cypress Exported Projects


Information in this knowledgebase article applies to:

  • MDK-ARM V5 All versions

SYMPTOM

After exporting a Cypress PSoC 4 project to µVision 5, downloading the application from µVision to Flash with ULINK2 or ULINKpro results in the following error:

No Algorithm found for: 000000000H - 0000FFFFH

CAUSE

The Start and Size parameters in Options for Target - Utilities - Settings - RAM for Algorithm are incorrect for PSoC devices.

RESOLUTION

Set the Start parameter to 0x20000200 and the Size parameter to 0x3E00, then click OK and OK again to save the changes. The download should work now.

MORE INFORMATION

MORE INFORMATION

Last Reviewed: Wednesday, November 28, 2018