QUESTION

I have selected the ST-Link target debugger in my project, but when I flash my application or when I start the debugger an "Internal command error" comes up.

How can I overcome this error?

ANSWER

There are two solutions, as mentioned below:

1. Connect the target device under Reset as shown below in Debug Settings

2. To upgrade the ST-Link firmware.

Use the ST-Link Upgrader to proceed.

This tool is stored at:

[MDK install path]\ARM\STLink\ST-LinkUpgrade.exe

Note: If:

  • The connection is lost after several seconds with the message:
        Cannot access target. Shutting down debug session.
    
    

...and

  • The message "Internal command error" is briefly displayed in command window, before debug session exits,

Then investigate the following causes:

  • HAL_GPIO_DeInit() was used on debug pins. Check SWDIO/TMS and SWDIO/TCK pins in software layer.
  • The device somehow enters low power mode and disables debug pins.