Technical Support Support Resources
Product Information |
Technical SupportULINK: No Trace Synchronization on Freescale K70 BoardInformation in this knowledgebase article applies to:
SYMPTOMThe Trace Status line in the µVision debugger always displays "No Synchronization" when attempting to use the ETM Trace option in the Kinetis TWR-K70F120M board. The Trace hardware is enabled and the Core Clock setting corresponds to the CLOCK_SETUP value in the system_MK70F12.c file. CAUSEThe TWR-K70F120M board has a location for a 0 ohm shunt (R137, on the back side of the board) that connects the TraceClock signal from the JTAG connector (J11) to the MCU. Some TWR-K70F120M boards do not have this shunt installed. This shunt must be installed to use the ETM trace option. RESOLUTIONInstall a 0 ohm resistor (or a short piece of wire) at the R137 location. MORE INFORMATION
Last Reviewed: Thursday, June 14, 2012 | ||||||||||
|
|||||||||||