SYMPTOM

With an MCBSTM32E or MCBSTM32C board, ETM debugging is sometimes erratic using a Signum JTAGJet-Trace adapter.

CAUSE

The TRACE_MODE option in the Debug Initialization File STM32DBG.INI is set for Asynchronous operation.

RESOLUTION

  1. Close the debugger.
  2. Change the TRACE_MODE option in the Debug Initialization File to Synchronous: TRACEDATA Size 4.
  3. Restart the debugger.

Last Reviewed: Tuesday, August 18, 2009