Keil Logo

ULINK: CANNOT PROGRAM UPSD3422 DEVICE


Information in this article applies to:

  • C51 Version up to 8.02a
  • ULINK USB-JTAG Adapter

QUESTION

When I try to program my uPSD3422 device with ULINK, I get the following error message:

Erasing Flash…
Erasing PLD/ACR…
*** OBJ Read Error: Address 024000 is not available
                    in this device (Line xxx).

What is the reason for this error and how can I avoid it?

ANSWER

The UL2UPSD.DLL was created with invalid flash-sector information that made it impossible to download an application into the boot sector 2 and 3 of a uPSD3422 device.

This problem has been corrected and a new driver (which may be downloaded from the Attached Files section below) is now available. Extract this file into the \KEIL\C51\BIN\ folder of your C51 installation.

This patch is not required for C51 versions after Version 8.02a.

ATTACHED FILES

Request the files attached to this knowledgebase article.

FORUM THREADS

The following Discussion Forum threads may provide information related to this topic.

Last Reviewed: Sunday, January 28, 2007


Did this article provide the answer you needed?
 
Yes
No