Keil™, An ARM® Company

Technical Support

CARM: LPC2130 TIMER 1 DOESN'T RUN


Information in this article applies to:

  • CARM All Versions
  • CARM Version 2.00

SYMPTOM

On the LPC2130 device, Timer 1 does not run when the enable bit is set.

CAUSE

The LPC213x devices allow the user to turn off on-chip peripherals to conserve power.  You may have turned off power to Timer 1 by mistake.

RESOLUTION

Power to Timer 1 is turned on after a chip reset.  Make sure you set the bit PCTIM1(PCONP.2), when modifying the PCONP register.

Last Reviewed: Wednesday, January 10, 2007