QUESTION

The first time I downloaded my ADuC831 board, my application downloaded and ran properly. If I try to download ADuC831 board again, I get the following error:

Target System Does Not Respond

Cycling board power or pressing the Reset button doesn't help. What's wrong?

ANSWER

ADuC83x boards must be in serial download/debug mode before they will accept download data. The following push button sequence puts the board in this mode:

  1. Push and hold the Serial Download button,
  2. Push and release the Reset button,
  3. Release the Serial Download button

After doing this, the board should download normally.