Keil Logo

C51: INITIALIZING FAR DATA


Information in this article applies to:

  • C51 All Versions

SYMPTOM

I have a data object in far memory, that I initalize in the declaration. When I reach "main" in my program, this data object is blank.

CAUSE

Initialization of far data is disabled by default. You must explicitly turn it on.

RESOLUTION

To activate far data initialization, do the following:

  • copy Init.A51, from C:\Keil\C51\lib, to your project directory.
  • add this local copy to your project
  • edit the file, and change $SET (XBANK = 0) to $SET (XBANK = 1)
  • rebuild and run your program

You should now see the data in far memory initialized, once your program executes to Main.

MORE INFORMATION

SEE ALSO

Last Reviewed: Tuesday, January 16, 2007


Did this article provide the answer you needed?
 