Technical Support Support Resources Product Information | µVISION DEBUGGER: C8051F330 OSC READY BIT NOT SET IN SIMULATORInformation in this article applies to:
QUESTIONWhen using the simulator on the Silicon Labs (Cygnal) C8051F330, if I enable the Internal Low-Frequency Oscillator, the simulator never sets the Ready bit (OSCLRDY in OSCLCN). Shouldn't the simulator set this bit automatically? ANSWERYes, the simulator should do this. There is an update to the simulation drivers for Silicon Labs devices that corrects this behavior. To install this update, perform the following steps:
SEE ALSOATTACHED FILESRequest the files attached to this knowledgebase article. Last Reviewed: Monday, June 06, 2005 | |||||||
| ||||||||