MCB2100: CAN INTERFACE PROBLEMS


Information in this article applies to:

  • MCB2100 Evaluation Board Version 2

SYMPTOM

The CAN I/O port on the MCB2100 Board does not work as it should.

CAUSE

According to the schematics, the pins CANL and CANH are wired to pin 2 and 7 of the DB-9 connector. However, they are actually connected to pin 4 and pin 8.

RESOLUTION

Pin 4 and pin 8 are not used on the CAN connector. So the workaround is to connect pin 2 to pin 4 and pin 7 to pin 8 underneath the DB9 connectors.

STATUS

Most of the MCB2100 Version 2 boards are already shipped with a correction for that error. So check your Board first to see if it already has this fix.

MORE INFORMATION

SEE ALSO

ATTACHED FILES

Request the files attached to this knowledgebase article.

Last Reviewed: Monday, October 23, 2006


Did this article provide the answer you needed?
 