Technical Support Support Resources
Product Information | A166: CALL GIVES WARNING L21 (DATA TYPES SLIGHTLY DIFFERENT)Information in this article applies to:
QUESTIONI have written an assembler program and at the linker level I get the message: WARNING L21: DATA TYPES SLIGHTLY DIFFERENT. Why do I get this warning and how can I avoid it? Below is my simplified program example: TEST1.A66
$SEGMENTED CASE
?PR?TEST SECTION CODE WORD 'FCODE'
PUBLIC func1
PUBLIC func2
func1 PROC FAR
NOP
func2: NOP
RET
func1 ENDP
?PR?TEST ENDS
END
TEST2.A66
$SEGMENTED CASE
EXTERN func1: FAR
EXTERN func2: FAR
?PR?TEST2 SECTION CODE WORD 'FCODE'
TEST2 PROC FAR
CALL func1
CALL func2
RET
TEST2 ENDP
?PR?TEST2 ENDS
END
The Linker outputs:
*** WARNING L21: DATA TYPES SLIGHTLY DIFFERENT
SYMBOL: func2
MODULE: A1.OBJ (A1)
ANSWERThis warning indicates that the linker assumes a different definition for the PUBLIC symbol func2. By default, all labels are considered as NEAR, therefore you get this linker warning. You can avoid this warning when you define the label as FAR. Modified source code of module TEST1.A66:
:
:
func1 PROC FAR
NOP
func2: LABEL FAR
NOP
RET
func1 ENDP
:
: