Technical Support

RTX166: HLDEN BIT CLEARED BY OS


Information in this article applies to:

  • RTX166 Version 3.10a

QUESTION

RTX166 V3 appears to clear the HLDEN bit in the PSW. My application needs to use external bus arbitration. Is there a time when the HLDEN bit can be set but not cleared by RTX166?

ANSWER

This was a problem in RTX166 Version 3 which has been corrected in RTX166 Version 4. The context switch routines were not using the correct mask value when resetting the PSW.

Contact our sales department for information on upgrading your real-time operating system.

Last Reviewed: Tuesday, July 19, 2005


Did this article provide the answer you needed?
 
Yes
No
Not Sure