Keil™, An ARM® Company

Technical Support

BL51: FATAL ERROR 228 (RAMSIZE OUT OF RANGE)


Information in this article applies to:

  • C51 Version 6.00 Beta
  • C51 Version 6.00

QUESTION

I receive the following linker error message whenever I use any of the Triscend chips in µVision2.

FATAL ERROR L228: RAMSIZE OUT OF RANGE

It appears that µVision2 sets the RAMSIZE as 8192 bytes. This is incorrect. Is this a known problem?

ANSWER

Yes. This is a known problem in µVision V2.04. The device database entries for the Triscend chips were set with the wrong ramsize in the UV2.

RESOLUTION

Download and install C51 version 6.05 or later.

You may download the latest updates from the Keil Website.

Then open your project and reselect the Triscend Chip for your target and build the project.

MORE INFORMATION

Last Reviewed: Tuesday, July 19, 2005


Did this article provide the answer you needed?
 
Yes
No
Not Sure