Product Information Device Database® Evaluation Software Compliance Testing Distributors | Peripheral SimulationFor Atmel AT91SAM7XC128 — Real-time Timer Simulation support for this peripheral or feature is comprised of: - Dialog boxes which display and allow you to change peripheral configuration.
These simulation capabilities are described below. Real-time Timer Dialog
The Real-time Timer Dialog shows the current state of the on-chip Real-time Timer. You can change Real-time Timer settings using the controls in this dialog. Mode - RTT_MR (Mode Register) holds the parameters that control the timer. They are:
- RTPRES (Real-time Prescaler Value) holds the number of SCLK periods (16-bits) required to increment the real-time timer.
- RTTRST (Real-time Timer Restart) reloads and restarts the clock divider with a the new programmed value, and resets the 32-bit counter.
- RTTINCIEN (Real-time Timer Increment Interrupt Enable) allows the RTTINC bit to trigger an interrupt.
- ALMIEN (Alarm Interrupt Enable) allows the ALMS bit to trigger an interrupt.
Alarm - RTT_AR (Alarm Register) holds the ALMV value.
- ALMV (Alarm Value) defined the 32-bit alarm value compared to the Real-time Timer.
Value - RTT_VR (Value Register) holds the CRTV value.
- CRTV (Current Real-time Value) displays the current 32-bit real-time value.
Status - RTT_SR (Status Register) holds the ALMS and the RTCINC values.
- ALMS (Real-time Alarm Status) is set if an alarm has occurred since the last read of RTT_SR.
- RTCINC (Real-time Timer Increment) is set if the Real-time Timer has been incremented since the last read of RTT_SR.
|
|