Product Information Device Database® Evaluation Software Compliance Testing Distributors | Peripheral SimulationFor Infineon XC164CM-4F — Timer Block GPT1 (T2, T3, T4) Simulation support for this peripheral or feature is comprised of: - Dialog boxes which display and allow you to change peripheral configuration.
These simulation capabilities are described below. Timer/Counter 2 Dialog
The Timer/Counter 2 dialog allows you to view and change the SFRs associated with Timer/Counter 2. This timer/counter is a general purpose unit which may be used for timing, counting, and so on. - Mode contains the operating mode and the input selector for the timer.
Direction - T2UDE (External Up/Down Enable) is set to let T2EUD control direction.
- T2EUD (External Up/Down Control Input) when T2UDE is set, this external input controls the count direction.
- T2UD is the timer up/down control. It can also reverse the count direction selected in T2EUD, when T2UDE is set.
- Direction displays whether the timer/counter counts up or down.
Status - Status displays the current status of the timer.
- T2 contains the value of the T2 SFR which is the current timer value or count.
- T2CON contains the value of the T2CON SFR which is the current configuration for Timer 2.
- T2R (Timer 2 Run Flag) is set when Timer 2 is running.
- T2IN is the Timer 2 External Input pin.
- T2IR (Timer 2 Interrupt Request Flag) is set when the Timer 2 overflows.
- T2EDGE (Timer 2 Edge Detection Flag) is set when a count edge is detected.
- T2CHDIR (Timer 2 Count Direction Change Flag) is set each time the count direction changes.
- T2IRDIS (Timer 2 Interrupt Disable Flag) is set to disable the Timer 2 Interrupt.
- T2RDIR (Timer 2 Count Rotation Direction Flag) when set Timer 2 counts up, when reset, Timer 2 counts down. This flag controls direction when external up/down control (T2UDE) is not enabled.
Timer/Counter 3 Dialog
The Timer/Counter 3 dialog allows you to view and change the SFRs associated with Timer/Counter 3. This timer/counter is a general purpose unit which may be used for timing, counting, and so on. - Mode contains the operating mode and the input selector for the timer.
Direction - T3UDE (External Up/Down Enable) is set to let T3EUD control direction.
- T3EUD (External Up/Down Control Input) when T3UDE is set, this external input controls the count direction.
- T3UD is the timer up/down control. It can also reverse the count direction selected in T3EUD, when T3UDE is set.
- Direction displays whether the timer/counter counts up or down.
Block Prescaler - BPS1 (Block Prescaler Control) selects the clock divider (4, 8, 16 or 32) for the general purpose core timer(GPT1).
Output - T3OTL (Overflow Toggle Latch) toggles when Timer 3 overflows or underflows.
- T3OE (Overflow/Underflow Output Enable) is set to output the state of the Timer 3 toggle latch (T3OTL) on output pin T3OUT.
- T3OUT (Timer 3 Output Pin) contains the state of the the Timer 3 output pin.
Status - Status displays the current status of the timer.
- T3 contains the value of the T3 SFR which is the current timer value or count.
- T3CON contains the value of the T3CON SFR which is the current configuration for Timer 3.
- T3R (Timer 3 Run Flag) is set when Timer 3 is running.
- T3IN is the Timer 3 External Input pin.
- T3IR (Timer 3 Interrupt Request Flag) is set when the Timer 3 overflows.
- T3EDGE (Timer 3 Edge Detection Flag) is set when a count edge is detected.
- T3CHDIR (Timer 3 Count Direction Change Flag) is set each time the count direction changes.
- T3RDIR (Timer 3 Count Rotation Direction Flag) when set Timer 3 counts up, when reset, Timer 3 counts down. This flag controls direction when external up/down control (T3UDE) is not enabled.
Timer/Counter 4 Dialog
The Timer/Counter 4 dialog allows you to view and change the SFRs associated with Timer/Counter 4. This timer/counter is a general purpose unit which may be used for timing, counting, and so on. - Mode contains the operating mode and the input selector for the timer.
Direction - T4UDE (External Up/Down Enable) is set to let T4EUD control direction.
- T4EUD (External Up/Down Control Input) when T4UDE is set, this external input controls the count direction.
- T4UD is the timer up/down control. It can also reverse the count direction selected in T4EUD, when T4UDE is set.
- Direction displays whether the timer/counter counts up or down.
Status - Status displays the current status of the timer.
- T4 contains the value of the T4 SFR which is the current timer value or count.
- T4CON contains the value of the T4CON SFR which is the current configuration for Timer 4.
- T4R (Timer 4 Run Flag) is set when Timer 4 is running.
- T4IN is the Timer 4 External Input pin.
- T4IR (Timer 4 Interrupt Request Flag) is set when the Timer 4 overflows.
- T4EDGE (Timer 4 Edge Detection Flag) is set when a count edge is detected.
- T4CHDIR (Timer 4 Count Direction Change Flag) is set each time the count direction changes.
- T4IRDIS (Timer 4 Interrupt Disable Flag) is set to disable the Timer 4 Interrupt.
- T4RDIR (Timer 4 Count Rotation Direction Flag) when set Timer 4 counts up, when reset, Timer 4 counts down. This flag controls direction when external up/down control (T4UDE) is not enabled.
|
|